How do I install and pair my relay micro-module (dry contact / ON-OFF) in Snugr?
This micro-module controls equipment through a relay (ON/OFF or dry contact depending on wiring). It is powered by 230 V AC and intended for indoor use.
SIN-2-1-XX-FR (2)
Key points before installation
-
Turn power off at the breaker panel before wiring.
SIN-2-1-XX-FR (2)
-
Max power: 2300 W (resistive load). Switching capability: 230 V AC – 10 A (and 30 V DC – 10 A).
SIN-2-1-XX-FR (2)
-
Heat sensitive: operating temperature -10 °C to 40 °C. Avoid hot, enclosed areas—do not install it directly behind a radiator.
SIN-2-1-XX-FR (2)
-
Install inside a compliant junction box and keep away from liquids.
SIN-2-1-XX-FR (2)
1) Wiring (summary)
Manual terminals: N (neutral), L (line), I1/I2 inputs (optional wired switch), relay output terminals. Up to 2.5 mm² per terminal (8 mm stripping).
SIN-2-1-XX-FR (2)
Exact wiring depends on the use case.
SIN-2-1-XX-FR (2)
2) Pair the module with Snugr (installation wizard)
-
Open Snugr (local or remote).
-
Go to Settings → Installation.
-
Click Add a device.
-
Select the appropriate type (relay / controller / micro-module, depending on wording).
-
Select (or create) the room.
-
Click Start pairing.
-
The module must be powered. Enter pairing by doing 3 quick consecutive presses on the module button: the LED blinks red.
SIN-2-1-XX-FR (2)
-
Wait for confirmation (the manual mentions about 30 seconds).
SIN-2-1-XX-FR (2)
3) Reset (if needed)
-
Press and hold the button for more than 5 seconds: the LED blinks orange.
SIN-2-1-XX-FR (2)
-
Then do a short press to confirm. The LED blinks red/green alternately, then turns green.
SIN-2-1-XX-FR (2)
-
Pair again via Snugr.